
The Agilent Micro 990 GC offers a turn-key solution that combines compact performance with high-efficiency analysis. This small but powerful system is ideal for labs with limited space, but high demands for reliability. Wasson-ECE Instrumentation adds significant value by offering additional services such as custom configurations, sampling systems, installation, and application-specific solutions. This ensures the Micro 990 GC is fine-tuned for optimal performance in your environment.
What's Included in the Turn-Key Solution:
• Pre-Configured Agilent Micro 990 GC: Fully assembled with your selected detector and pre-configured for your needs.
• Custom Integration by Wasson-ECE: Wasson-ECE offers tailored configurations and modifications to meet the exact needs of your lab or mobile testing unit. Our experienced team ensures that the system is perfectly designed with your unique application in mind.
• Software Suite: Includes Agilent OpenLAB ChemStation, EZChrom, or OpenLAB CDS for quick setup.
• Expert Installation & Calibration: Wasson-ECE ensures that the Agilent Micro 990 GC is installed correctly and calibrated to meet your analytical needs, providing you with immediate and accurate results.
• Training & Support: Wasson-ECE offers comprehensive training to ensure that your team can operate the system efficiently, as well as providing ongoing technical support when needed.
• Maintenance & Support Packages: Wasson-ECE provides flexible service contracts for routine maintenance, ensuring continued operation at peak performance.
Benefits of Turn-Key Solutions:
• Space-Saving and Powerful: Get the full analytical capability of the Agilent Micro 990 GC in a compact, user-friendly format, supported by Wasson-ECE’s integration expertise with up to four channels.
• Wasson-ECE Expertise: Custom configurations and ongoing support from Wasson-ECE ensure the system is optimized for your specific applications and requirements.
• Efficient, Low-Cost Operation: Designed for labs with space or budget constraints, this solution is both affordable and energy-efficient, while delivering professional-grade results.
Features:
• Compact Design: The Micro 990 GC delivers full-scale GC performance in a smaller footprint, perfect for labs with limited space.
• Superior Sensitivity: Achieve highly accurate results with minimal sample sizes, thanks to enhanced detection capabilities.
• Intuitive Software: With Agilent's easy-to-use software, setup, data collection, and analysis are simplified.
• Multiple Channel Options: Includes up to 4 channels that can be custom configured for multiple analyses.
• Efficient Operation: Optimized for fast analysis without compromising accuracy or precision.
• Energy-Efficient: Low power consumption and minimal maintenance needs help lower operational costs over time.
For over 35 years, Wasson-ECE has delivered proven gas chromatography solutions for the industry's most demanding applications.
Compact Form Factor:
The Micro 990 GC is more than 50% smaller than traditional GCs, making it ideal for labs where space is at a premium, without compromising on analysis capabilities.
Low Power Consumption:
Unlike many other GCs, the Micro 990 is engineered for energy efficiency, helping users cut down on operational costs while delivering full performance.
Enhanced Ease of Use:
With an intuitive touchscreen interface and pzowerful software, the Micro 990 streamlines setup, analysis, and system monitoring, offering a user-friendly experience even for those new to chromatography.
- • Oven (Column) temperature range: 30-180°C* (*maximum temperature depends on column type)
- • Injector temperature range: 30-110°C
- • Sample inlet temperature range: 30-110°C
- • Pressure control: Electronic Pressure Control (EPC) for precise and consistent gas flow.
- • Detection Option: Thermal Conductivity Detector (TCD)
- • Connectivity: Remote access via Ethernet, USB, and Wifi.
- • Energy Efficiency: Designed for low power consumption, saving on long-term operating costs.
The Agilent Micro 990 GC offers a turn-key solution that combines compact performance with high-efficiency analysis. This small but powerful system is ideal for labs with limited space, but high demands for reliability. Wasson-ECE Instrumentation adds significant value by offering additional services such as custom configurations, sampling systems, installation, and application-specific solutions. This ensures the Micro 990 GC is fine-tuned for optimal performance in your environment.
What's Included in the Turn-Key Solution:
• Pre-Configured Agilent Micro 990 GC: Fully assembled with your selected detector and pre-configured for your needs.
• Custom Integration by Wasson-ECE: Wasson-ECE offers tailored configurations and modifications to meet the exact needs of your lab or mobile testing unit. Our experienced team ensures that the system is perfectly designed with your unique application in mind.
• Software Suite: Includes Agilent OpenLAB ChemStation, EZChrom, or OpenLAB CDS for quick setup.
• Expert Installation & Calibration: Wasson-ECE ensures that the Agilent Micro 990 GC is installed correctly and calibrated to meet your analytical needs, providing you with immediate and accurate results.
• Training & Support: Wasson-ECE offers comprehensive training to ensure that your team can operate the system efficiently, as well as providing ongoing technical support when needed.
• Maintenance & Support Packages: Wasson-ECE provides flexible service contracts for routine maintenance, ensuring continued operation at peak performance.
Benefits of Turn-Key Solutions:
• Space-Saving and Powerful: Get the full analytical capability of the Agilent Micro 990 GC in a compact, user-friendly format, supported by Wasson-ECE’s integration expertise with up to four channels.
• Wasson-ECE Expertise: Custom configurations and ongoing support from Wasson-ECE ensure the system is optimized for your specific applications and requirements.
• Efficient, Low-Cost Operation: Designed for labs with space or budget constraints, this solution is both affordable and energy-efficient, while delivering professional-grade results.
Features:
• Compact Design: The Micro 990 GC delivers full-scale GC performance in a smaller footprint, perfect for labs with limited space.
• Superior Sensitivity: Achieve highly accurate results with minimal sample sizes, thanks to enhanced detection capabilities.
• Intuitive Software: With Agilent's easy-to-use software, setup, data collection, and analysis are simplified.
• Multiple Channel Options: Includes up to 4 channels that can be custom configured for multiple analyses.
• Efficient Operation: Optimized for fast analysis without compromising accuracy or precision.
• Energy-Efficient: Low power consumption and minimal maintenance needs help lower operational costs over time.
For over 35 years, Wasson-ECE has delivered proven gas chromatography solutions for the industry's most demanding applications.
Compact Form Factor:
The Micro 990 GC is more than 50% smaller than traditional GCs, making it ideal for labs where space is at a premium, without compromising on analysis capabilities.
Low Power Consumption:
Unlike many other GCs, the Micro 990 is engineered for energy efficiency, helping users cut down on operational costs while delivering full performance.
Enhanced Ease of Use:
With an intuitive touchscreen interface and pzowerful software, the Micro 990 streamlines setup, analysis, and system monitoring, offering a user-friendly experience even for those new to chromatography.
- • Oven (Column) temperature range: 30-180°C* (*maximum temperature depends on column type)
- • Injector temperature range: 30-110°C
- • Sample inlet temperature range: 30-110°C
- • Pressure control: Electronic Pressure Control (EPC) for precise and consistent gas flow.
- • Detection Option: Thermal Conductivity Detector (TCD)
- • Connectivity: Remote access via Ethernet, USB, and Wifi.
- • Energy Efficiency: Designed for low power consumption, saving on long-term operating costs.
The Micro 990 GC is specifically designed for comprehensive natural gas analysis, including:
Pipeline gas monitoring - Real-time analysis of methane, ethane, propane, butanes, and heavier hydrocarbons (C1-C6+)
Calorific value calculations - Compliant with GPA2172 standards for energy content determination
Custody transfer applications - Accurate compositional analysis for commercial gas transactions
Gas quality monitoring - Detection of impurities and contaminants like H2S, CO2, and nitrogen
Optimized for renewable energy applications:
Biogas plant monitoring - Analysis of CH4, CO2, H2S, and other components in anaerobic digestion processes
Landfill gas analysis - Monitoring methane recovery operations and emission control
Process optimization - Real-time feedback for maximizing biogas production efficiency
Safety monitoring - Detection of trace contaminants and toxic compounds
Critical for hydrocarbon processing:
Refinery gas analysis - C1-C6 hydrocarbon separation including olefins and paraffins
Process stream monitoring - Real-time analysis of cracker feeds, reformer off-gas, and reactor effluents
Light hydrocarbon analysis - Separation of ethylene/ethane, propylene/propane for polymer feedstock
Permanent gas analysis - H2, CO, CO2, N2, O2 for process optimization and safety
Environmental monitoring - Stack gas analysis and emission monitoring
Industrial gas quality control - Purity analysis of specialty gases
Research and development - Laboratory analysis of gas mixtures and reaction products
Safety applications - Leak detection and hazardous gas monitoring in industrial facilities
The Micro 990 GC's fast analysis times (typically 30-240 seconds), compact design, and ability to operate in harsh environments make it ideal for both laboratory and online process applications across these markets.
• Analysis Time:
30-240 seconds (vs. traditional GC: 10-30 minutes)
• Sample Throughput:
Up to 120 analyses/hour with dual channels
• Ready Time:
<10 minutes from cold start (vs. 30-60 minutes for bench-top GC)
• Temperature Equilibration:
±0.2°C column stability, ±1°C injector stability
• Single Channel Laboratory - Benchtop analysis with method development
• Dual Channel Standard - Most common configuration for routine analysis
• Triple Channel Extended - Requires extension cabinet for complex applications
• Quad Channel Maximum - Complete analytical capability for comprehensive gas analysis
• Beswick Pressure Reducer
• Beswick Pressure Reducer + Genie Filter
• Rotameter + Genie Filter
• Touch Screen LCD
• Genie Filter
• Micro Gasifier
• Manual Injection
• Stream Selection Valve
• External Sample Filter
• Manual Injection Via Septum Nut or Luer Lock Injection Port

• Front Heated Inlet - Standard sample introduction, 30-110°C
• Multi-position Valve - Multiple sample stream capability
• Manual Injection Ports - Syringe injection for discrete samples
• Pressure Regulation - Optional built-in regulators for high-pressure samples
- • Oven (Column) temperature range: 30-180°C* (*maximum temperature depends on column type)
- • Injector temperature range: 30-110°C
- • Sample inlet temperature range: 30-110°C
- • Pressure control: Electronic Pressure Control (EPC) for precise and consistent gas flow.
- • Detection Option: Thermal Conductivity Detector (TCD)
- • Connectivity: Remote access via Ethernet, USB, and Wifi.
- • Energy Efficiency: Designed for low power consumption, saving on long-term operating costs.
- Sample Capacity: 12 × 500mL or 9 × 1L sample cylinders
- Temperature Range: Ambient to 135°C
- Temperature Stability: ±2°C
- Pressure Rating: Up to 1000 psig
- Transfer Line Heating: Up to 135°C
- Purge Gas: Nitrogen or Helium compatible
- Vacuum System: Integrated vacuum pump for sample line evacuation
- Control System: PC-based Windows software
- Communication: RS-232/USB interface
- Standards Compliance: ASTM D1945, ASTM D1946, ISO 6974 compatible
- Safety Features: Over-temperature protection, pressure relief, emergency stop
- Dimensions: 16.5" W × 19.3" D × 13.4" H (42 × 49 × 34 cm)
- Weight: Approx. 40 lbs, depending on number of channels and selected options
- Power Supply: 100-240 V, 50/60 Hz
- Input Power: 100-240 VAC, 50/60 Hz
- Power Consumption: 150W maximum (12 VDC from external adapter)
- Power Supply: Model GST220A12-AG2 (Part # 0950-5837)
- Installation Category: II (overvoltage protection)
- Circuit Requirements: Dedicated 15A circuit recommended
- Grounding: Protective earth ground mandatory
- Output: 12.0 VDC, 150W
- Efficiency: >85% at full load
- Operating Temperature: -30°C to +70°C
- Safety Standards: UL60950-1, EN60950-1 compliant
- EMC Compliance: CISPR22 Class B, FCC Part 15
- Temperature Range: 0°C to 50°C (32°F to 122°F)
- Humidity: 10% to 95% RH (non-condensing)
- Altitude: Up to 2,000 meters above sea level

Wasson-ECE Instrumentation
101 Rome Ct., Fort Collins, Colorado USA 80524
Phone: +1 (970) 221-9179
Fax: +1 (970) 221-9364
© 2025. All Rights Reserved.
The artistic application of human intelligence. ®